Leo company's product prototype.
Full Automatic Fast Opening Membrane Filter Press Operation Problems and Trouble Shooting Method
Filter Press Operation and Working Instructions for Fast Opening Automatic Membrane Filter Press
1. Filter Press Hydraulic station problems
A. big noise from filter press oil hydraulic pump
Trouble shooting method: check hydraulic oil pump rotating direction
Check hydraulic oil pump axle, disassemble the hydraulic oil pump body ,if there is axle problem,replace the axle.
B. hydraulic oil pump start to work too frequently during filter press closing
Maybe due to hydraulic system or high pressure stage safety check valve set too low, if hydraulic hose any hydraulic oil leakage, replace sealing rings; if pressure gauge showed high pressure stage safety check valve pressure is not at the pre-set scope.The other reason is damage of cylinder sealing rings damage, replace all the sealing rings
C. hydraulic pump can’t reach the highest pressure in need
D. hydraulic pump can’t pump oil
Low hydraulic oil level, add more hydraulic oil to the required oil level
Bad sealing for The hydraulic pump thread, tighten the sealing units again
Damaged piston inside the piston pump, replace hydraulic piston
Leo Filter Press Fast Opening Hydraulic Filter Press Brief Instructions:
Filter press plate size:400mm to 2000mm
Membrane filter press plate size: 400mm to 2000mm
Max working pressure: 20bar
Chamber volume from 10L to 1000L
Max Membrane squeezing pressure: 16bar
Filter Plate Opening method : fast opening by hydraulic system